The Ultimate Guide to DZ47 Breakers: Understanding the Miniature Circuit Breakers
In the world of electrical safety and efficiency, DZ47 circuit breakers stand out as a reliable choice for modern installations. Used extensively in residential, commercial, and industrial applications, these miniature circuit breakers (MCBs) protect circuits from overload and short-circuit events. This guide will explore the different types of DZ47 breakers, their applications, technical features, and installation considerations.
Comparison of DZ47 Breakers
Type | Rated Current (A) | Rated Voltage (V) | Applications |
---|---|---|---|
DZ47-63 | 6, 10, 16, 20, 25, 32, 40, 50, 63 | 230/400 | Residential, commercial lighting, and power systems |
DZ47-125 | 63, 80, 100, 125 | 230/400 | Power distribution in industrial settings |
DZ47-60 | 60 | 230/400 | Residential and commercial power management |
DZ47sZ-63 | 6, 10, 16, 20, 25, 32 | 230 | Lighting circuits in homes and buildings |
Understanding DZ47 Circuit Breakers
DZ47 circuit breakers are designed for use in AC 50/60Hz environments, providing effective protection against overload and short-circuit conditions. Their compact design allows for easy installation on standard rails, making them ideal for various applications.
Applications of DZ47 Breakers
DZ47 breakers find their utility in several fields:
- Residential Use: Commonly found in homes for lighting and power distribution.
- Commercial Applications: Used in offices and retail environments to protect electrical equipment.
- Industrial Settings: Essential for machinery and production lines, safeguarding against electrical faults.
Key Features
DZ47 circuit breakers boast several notable features:
- Quick Tripping Mechanism: Designed to react swiftly to fault conditions, minimizing the risk of damage.
- High Breaking Capacity: Capable of handling significant fault currents, ensuring safety.
- Flame-Retardant Materials: Constructed from materials that withstand high temperatures and resist ignition.
Technical Specifications of DZ47 Circuit Breakers
Here’s a detailed comparison of technical features for various DZ47 models:
Model | Rated Current (A) | Rated Voltage (V) | Breaking Capacity (kA) | Tripping Characteristics |
---|---|---|---|---|
DZ47-63 | 6, 10, 16, 20, 25, 32 | 230/400 | 10 | C-type, D-type |
DZ47-125 | 63, 80, 100, 125 | 230/400 | 10 | C-type, D-type |
DZ47-60 | 60 | 230/400 | 10 | C-type |
DZ47sZ-63 | 6, 10, 16, 20, 25, 32 | 230 | 10 | C-type |
Installation Guidelines
Installing DZ47 breakers requires adherence to strict guidelines to ensure optimal performance and safety:
Site Conditions
- Temperature Range: Ideal installation temperature is between -5°C to +40°C.
- Altitude: Should not exceed 2000m above sea level.
- Humidity Levels: Maximum relative humidity of 50% at 40°C, with permissible higher levels at lower temperatures.
Mounting Instructions
DZ47 breakers should be mounted on TH35-7.5 rails. The installation should be vertical, with the handle positioned upwards to indicate the power-on state. Additionally, it is crucial to avoid installation in areas prone to heavy impact or vibration.
Related Video
Conclusion
DZ47 circuit breakers are essential components in modern electrical systems, providing safety and reliability across various applications. With their robust design, quick tripping mechanisms, and compliance with international standards, they are a trusted choice for professionals and homeowners alike. The versatility of models such as the DZ47-63 and DZ47-125 allows for application in diverse electrical systems, from simple household circuits to complex industrial installations.
FAQ
What is a DZ47 circuit breaker?
A DZ47 circuit breaker is a miniature circuit breaker designed to protect electrical circuits from overload and short-circuit conditions. They are widely used in residential, commercial, and industrial applications.
What are the main applications of DZ47 breakers?
DZ47 breakers are primarily used in residential electrical systems for lighting and power distribution, as well as in commercial and industrial settings to protect machinery and equipment.
What is the breaking capacity of DZ47 circuit breakers?
Most DZ47 circuit breakers, like the DZ47-63 and DZ47-125, typically have a breaking capacity of 10kA, which allows them to handle significant fault currents safely.
Are DZ47 breakers easy to install?
Yes, DZ47 breakers are designed for easy installation on standard TH35-7.5 rails. They should be mounted vertically, with consideration for site conditions like temperature and humidity.
What materials are used in DZ47 circuit breakers?
DZ47 circuit breakers are constructed using flame-retardant and impact-resistant plastics to ensure safety and durability in various environments.
What are the ambient conditions for installing DZ47 breakers?
The recommended ambient temperature for installation ranges from -5°C to +40°C, with a maximum altitude of 2000m and humidity levels not exceeding 50% at 40°C.
What types of tripping characteristics do DZ47 breakers have?
DZ47 circuit breakers typically feature C-type and D-type tripping characteristics, which are designed to protect conventional loads and those with high inrush currents, respectively.
Can DZ47 breakers be used for outdoor applications?
While DZ47 breakers can be used in various environments, they should not be installed in areas exposed to rain, snow, or extreme vibration, as these conditions can affect their performance.
What standards do DZ47 circuit breakers comply with?
DZ47 circuit breakers comply with standards such as IEC60898 and GB10963, ensuring they meet international safety and quality requirements.
Where can I purchase DZ47 circuit breakers?
DZ47 circuit breakers are available from various manufacturers and suppliers, including websites such as www.txele.com, www.usfull.com, and www.andeligroup.com.